Electromedical Device And Expert System for Early Detection of Hyperemesis Gravidarum

Main Article Content

Fitrilina Fitrilina
Ganesha
Yanolanda Suzantry Handayani
Alex Surapati
Rahayu Trisetyowati Untari
Heru Dibyo Laksono
Melda Latif

Keywords

Certainty Factor, Hyperemesis Gravidarum, Electromedical Device, Pregnancy

Abstract

Hyperemesis Gravidarum (HG) is a pregnancy complication that is often overlooked as it is typically considered normal. If HG is not properly treated, nutrition will not be fulfilled which can negatively affect maternal and fetal health and even maternal and fetal death. The exact cause of HG is not identified, so there are no effective preventive methods. However early detection can help for prompt and appropriate treatment. Therefore, a monitoring system for pregnancy conditions was designed for HG early detection. This system employs the MPX5050 DP pressure sensor for measuring blood pressure, the MAX30100 for assessing maternal heart rate and oxygen saturation, the MAX4466 sensor for monitoring fetal heart rate, and an expert system using the certainty factor method to diagnose the probability of hyperemesis gravidarum. The expert system achieves an accuracy of 93.33%. In comparison to the aneroid sphygmomanometer, the designed sphygmomanometer reveals a mean difference of 3.5 mmHg for diastolic pressure, with a standard deviation below 8 mmHg for both systolic and diastolic pressures. The measurement of heart rate and oxygen saturation has a deviation of 1.8 % and 1.02 % respectively. These deviations align with the standards specified by the Ministry of Health for medical devices. For the fetal heart rate, the mean deviation is 3.4 bpm, and the measurement error is 2.38%. Thus, this system can be utilized to monitor pregnancy conditions, enabling the early detection of hyperemesis gravidarum

References

[1] Susilawati and Erlyna Evasari, “Hubungan Gravida, Umur dan Pendidikan Ibu dengan Hiperemesis Gravidarum,” J. Obs. Sci., vol. 4, pp. 435–452, 2017.
[2] F. P. McCarthy, J. E. Lutomski, and R. A. Greene, “Hyperemesis gravidarum: Current perspectives,” Int. J. Womens. Health, vol. 6, no. 1, pp. 719–725, 2014, doi: 10.2147/IJWH.S37685.
[3] A. D. Nurbaity, A. Candra, and D. Y. Fitranti, “Faktor Risiko Hiperemesis Gravidarum Pada Ibu Hamil Di Semarang,” J. Nutr. Coll., vol. 8, no. 3, pp. 123–130, 2019, doi: 10.14710/jnc.v8i3.25801.
[4] K. W. MacGibbon, "Hyperemesis Gravidarum: Strategies to Improve Outcomes," J. Infus. Nurs., vol. 43, no. 2, pp. 78–96, 2020, doi: 10.1097/NAN.0000000000000363.
[5] E. Susanti, F. Firdayanti, and N. Haruna, “Manajemen Asuhan Kebidanan Antenatal Pada Ny ‘S’ dengan Hiperemesis Gravidarum Tingkat II di Rs TNI Angkatan Laut Jala Ammari Pada Tanggal 27 Mei-18 Juli 2018,” J. Midwifery, vol. 1, no. 2, pp. 79–91, 2019, doi: 10.24252/jmw.v1i2.10557.
[6] RCOG and The Royal College of Obstetricians and Gynaecologist, "The Management of Nausea and Vomiting of Pregnancy and Hyperemesis Gravidarum: Green-top Guideline No. 69," RCOG Green-top Guidel. No. 69, no. 1, pp. 1–27, 2016.
[7] A. Ardani, “Perbandingan Efektifitas Pemberian Terapi Minuman Jahe dengan Minuman Kapulaga Terhadap Morning Sickness pada Ibu Hamil Trimester I di Keluarahan …,” Semarang STIKES Ngudi Waluyo Ung., pp. 1–11, 2013, [Online]. Available: http://www.academia.edu/download/38030163/3657_mual_muntah.pdf
[8] S. Rofi’ah, S. Widatiningsih, and A. Arfiana, “Studi Fenomenologi Kejadian Hiperemesis Gravidarum Pada Ibu Hamil Trimester I,” J. Ris. Kesehat., vol. 8, no. 1, p. 41, 2019, doi: 10.31983/jrk.v8i1.3844.
[9] B. Basiroh and S. W. Kareem, "Analysis of Expert System for Early Diagnosis of Disorders During Pregnancy Using the Forward Chaining Method," Int. J. Artif. Intell. Res., vol. 5, no. 1, pp. 44–52, 2021, doi: 10.29099/ijair.v5i1.203.
[10] E. F. Wati and A. Puspitasari, “Expert System for Diagnosing Pregnancy Complaints by Forward Chaining,” SinkrOn, vol. 5, no. 1, p. 7, 2020, doi: 10.33395/sinkron.v5i1.10593.
[11] A. Abdillah, N. Nurajijah, and I. Nawawi, "Perancangan Sistem Pakar Diagnosa Penyakit Kehamilan Berbasis Web," J. Techno Nusa Mandiri, vol. 15, no. 2, p. 115, 2018, doi: 10.33480/techno.v15i2.910.
[12] D. S. A. Maylawati, M. A. Ramdhani, W. B. Zulfikar, I. Taufik, and W. Darmalaksana, "Expert system for predicting the early pregnancy with disorders using artificial neural network," 2017 5th Int. Conf. Cyber IT Serv. Manag. CITSM 2017, 2017, doi: 10.1109/CITSM.2017.8089243.
[13] S. Rani and P. K. Mistri, "Oxygen Saturation as a Predictor of Adverse Maternal Outcomes in Women with Preeclampsia," Birat J. Heal. Sci., vol. 4, no. 1, pp. 582–585, 2019, doi: 10.3126/bjhs.v4i1.23926.
[14] M. Watanabe, H. Shinohara, and H. Kodama, "Nocturnal oxygen desaturation in the late third trimester of uncomplicated pregnancy for prediction of late-onset gestational hypertension," pp. 1–9, 2020, doi: 10.1111/jog.14362.
[15] K. Jasani, N. Patel, J. K, D. Rana, and S. Malhotra, "Variability in digital blood pressure measurement and normal sphygmomanometer - A randomized study," Natl. J. Physiol. Pharm. Pharmacol., no. 0, p. 1, 2019, doi: 10.5455/njppp.2020.10.1238109122019.
[16] Badan Pusat Statistik, “Survei Demografi Dan Kesehatan : Kesehatan Reproduksi Remaja 2017. In Badan Kependudukan dan Keluarga Berencana,” Survei Demogr. Dan Kesehat., p. 271, 2017, [Online]. Available: http://www.dhsprogram.com.
[17] V. Chourasia and A. Mittra, "Passive Acoustic Signal Acquisition System for Non-Invasive Fetal Heart Sound Monitoring Applications.," Internet J. Med. Technol., vol. 5, no. 1, pp. 1–8, 2012, doi: 10.5580/55f.
[18] F. Fitrilina, M. Albbi, I. Agustian, A. Herawati, and N. A. Massardi, “Sistem Peringatan Awal Resiko Preklamsia pada kehamilan menggunakan metoda Certainty Factor dan Android,” J. Nas. Tek. Elektro, vol. 10, no. 1, p. 45, 2021, doi: 10.25077/jnte.v10n1.896.2021.
[19] T. A. Munandar, Suherman, and Sumiati, "The Use of Certainty Factor with Multiple Rules for Diagnosing Internal Disease," Ijaiem, vol. 1, no. 1, pp. 58–64, 2012.
[20] M. S. Ali and M. H. Bhuyan, "Design and implementation of a low-cost blood pressure measuring device," ICECE 2018 - 10th Int. Conf. Electr. Comput. Eng., no. December, pp. 309–312, 2019, doi: 10.1109/ICECE.2018.8636728.
[21] B. Shahbabu, A. Dasgupta, K. Sarkar, and S. K. Sahoo, "Which is more accurate in measuring the blood pressure? A digital or an aneroid sphygmomanometer," J. Clin. Diagnostic Res., vol. 10, no. 3, pp. LC11–LC14, 2016, doi: 10.7860/JCDR/2016/14351.7458.
[22] S. K. Singha, K. Sarkar, and M. Ahmad, "An Easy Approach to Develop a Digital Blood Pressure Meter," 2nd Int. Conf. Electr. Comput. Commun. Eng. ECCE 2019, pp. 1–5, 2019, doi: 10.1109/ECACE.2019.8679246.
[23] “Kepmenkes 118-2014 Kompendium Alat Kesehatan (1).pdf.”

Most read articles by the same author(s)

1 2 > >>